{"id":2893,"date":"2025-10-27T07:38:19","date_gmt":"2025-10-27T07:38:19","guid":{"rendered":"https:\/\/jrhmeter.com\/?post_type=product&#038;p=2893"},"modified":"2025-10-27T07:38:19","modified_gmt":"2025-10-27T07:38:19","slug":"three-phase-multifunctional-energy-meter-guide-rail-type","status":"publish","type":"product","link":"https:\/\/jrhmeter.com\/ru\/product\/three-phase-multifunctional-energy-meter-guide-rail-type\/","title":{"rendered":"\u0422\u0440\u0435\u0445\u0444\u0430\u0437\u043d\u044b\u0439 \u043c\u043d\u043e\u0433\u043e\u0444\u0443\u043d\u043a\u0446\u0438\u043e\u043d\u0430\u043b\u044c\u043d\u044b\u0439 \u0441\u0447\u0435\u0442\u0447\u0438\u043a \u044d\u043d\u0435\u0440\u0433\u0438\u0438 (\u0442\u0438\u043f \u043d\u0430\u043f\u0440\u0430\u0432\u043b\u044f\u044e\u0449\u0435\u0439)"},"content":{"rendered":"<p class=\"p1\"><strong>\u0425\u0430\u0440\u0430\u043a\u0442\u0435\u0440\u0438\u0441\u0442\u0438\u043a\u0438 \u0442\u043e\u0432\u0430\u0440\u0430<\/strong><\/p>\n<p class=\"p1\">\u25a0The three-phase intelligent rail meter measures active and reactive power in both forward and reverse<\/p>\n<p class=\"p1\">directions. It simultaneously monitors A, B, and C phase voltages, currents, active\/reactive power,<\/p>\n<p class=\"p1\">power factor, grid frequency, and total power consumption, with maximum demand recording<\/p>\n<p class=\"p1\">capability. The meter stores cumulative data for active\/reactive power, forward\/reverse total, peak,<\/p>\n<p class=\"p1\">valley, and flat periods, with the multi-rate billing function available only in high-capacity models.<\/p>\n<p class=\"p1\">\u25a0You can set two time zones and two schedules per year, eight daily periods and four rates:<\/p>\n<p class=\"p1\">peak, peak, flat and valley. The minimum interval between periods is 1 5 minutes.<\/p>\n<p class=\"p1\">\u25a0The system features data wheel display and data key display functions. Users can access voltage, current,<\/p>\n<p class=\"p1\">power factor, frequency, active power, reactive power, forward\/reverse active energy, and forward\/reverse<\/p>\n<p class=\"p1\">reactive energy through panel buttons. If no button is pressed within 8 seconds, the system automatically<\/p>\n<p class=\"p1\">switches to 4-second wheel display mode.<\/p>\n<p class=\"p1\">\u25a0Optional display of maximum demand for U, I, P, and Q, along with total peak, valley, flat, and off-peak power consumption for active and reactive power.<\/p>\n<p class=\"p1\">\u25a0Features active and reactive power pulse outputs for meter calibration and remote energy<\/p>\n<p class=\"p1\">collection. The passive opto-isolated output port delivers a pulse width of 80ms \u00b1 20ms.<\/p>\n<p class=\"p1\">\u25cfThe clock error is less than 0.5s per day, with automatic switching of calendar, timing, and leap year.<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p class=\"p1\"><strong>Technical Parameter<\/strong><\/p>\n<table style=\"width: 100%; border-collapse: collapse; border-color: #e6e6e6;\" border=\"1\">\n<tbody>\n<tr>\n<td style=\"width: 25%; text-align: center; vertical-align: middle;\">\n<p class=\"p1\">Project<\/p>\n<\/td>\n<td style=\"width: 25%; text-align: center; vertical-align: middle;\">\n<p class=\"p1\">metric<\/p>\n<\/td>\n<td style=\"width: 25%; text-align: center; vertical-align: middle;\">\n<p class=\"p1\">Project<\/p>\n<\/td>\n<td style=\"width: 25%; text-align: center; vertical-align: middle;\">\n<p class=\"p1\">metric<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 25%; text-align: center; vertical-align: middle;\">\n<p class=\"p1\">Accuracy class<\/p>\n<\/td>\n<td style=\"width: 25%; text-align: center; vertical-align: middle;\">\n<p class=\"p1\">Active power: 0.5 level; reactive power: 2.0 level<\/p>\n<\/td>\n<td style=\"width: 25%; text-align: center; vertical-align: middle;\">\n<p class=\"p1\">\u0420\u0430\u0431\u043e\u0447\u0430\u044f \u0442\u0435\u043c\u043f\u0435\u0440\u0430\u0442\u0443\u0440\u0430<\/p>\n<\/td>\n<td style=\"width: 25%; text-align: center; vertical-align: middle;\">\n<p class=\"p1\">-10\u2103\uff5e+45\u2103<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 25%; text-align: center; vertical-align: middle;\">\n<p class=\"p1\">Rated voltage<\/p>\n<\/td>\n<td style=\"width: 25%; text-align: center; vertical-align: middle;\">\n<p class=\"p1\">3\u00d7220\/380V<\/p>\n<\/td>\n<td style=\"width: 25%; text-align: center; vertical-align: middle;\">\n<p class=\"p1\">Relative humidity<\/p>\n<\/td>\n<td style=\"width: 25%; text-align: center; vertical-align: middle;\">\n<p class=\"p1\">\u226495% (no condensation)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 25%; text-align: center; vertical-align: middle;\">\n<p class=\"p1\">Working voltage<\/p>\n<\/td>\n<td style=\"width: 25%; text-align: center; vertical-align: middle;\">\n<p class=\"p1\">0.9-1.1Un<\/p>\n<\/td>\n<td style=\"width: 25%; text-align: center; vertical-align: middle;\">\n<p class=\"p1\">Power dissipation<\/p>\n<\/td>\n<td style=\"width: 25%; text-align: center; vertical-align: middle;\">\n<p class=\"p1\">Voltage\/current circuit &lt;5VA4VA<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 25%; text-align: center; vertical-align: middle;\">\n<p class=\"p1\">Current Specifications<\/p>\n<\/td>\n<td style=\"width: 25%; text-align: center; vertical-align: middle;\">\n<p class=\"p1\">1. 5(6)A 5(60)A 20(80)A<\/p>\n<\/td>\n<td style=\"width: 25%; text-align: center; vertical-align: middle;\">\n<p class=\"p1\">Clock error<\/p>\n<\/td>\n<td style=\"width: 25%; text-align: center; vertical-align: middle;\">\n<p class=\"p1\">\u22640.5s\/d<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 25%; text-align: center; vertical-align: middle;\">\n<p class=\"p1\">Reference frequency<\/p>\n<\/td>\n<td style=\"width: 25%; text-align: center; vertical-align: middle;\">\n<p class=\"p1\">50Hz or 60Hz<\/p>\n<\/td>\n<td style=\"width: 25%; text-align: center; vertical-align: middle;\">\n<p class=\"p1\">RS485 serial port<\/p>\n<\/td>\n<td style=\"width: 25%; text-align: center; vertical-align: middle;\">\n<p class=\"p1\">MODBUS-RTU\u3001<\/p>\n<p class=\"p1\">DT\/T645-2007 protocol<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 25%; text-align: center; vertical-align: middle;\">\n<p class=\"p1\">Starting current<\/p>\n<\/td>\n<td style=\"width: 25%; text-align: center; vertical-align: middle;\">\n<p class=\"p1\">Direct \/ CT access:<\/p>\n<p class=\"p1\">0.004Ib\/0.002Ib<\/p>\n<\/td>\n<td style=\"width: 25%; text-align: center; vertical-align: middle;\">\n<p class=\"p1\">Traffic rate<\/p>\n<\/td>\n<td style=\"width: 25%; text-align: center; vertical-align: middle;\">\n<p class=\"p1\">9600bps (default), 19200\/<\/p>\n<p class=\"p1\">4800\/2400\/1200bps optional<\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>","protected":false},"excerpt":{"rendered":"<p class=\"p1\"><strong>Product Introduction<\/strong><\/p>\n<p class=\"p1\">The device features 35mm standard rail mounting with a remote RS-485 communication interface, meeting all<\/p>\n<p class=\"p1\">technical requirements for electricity meters specified in GB\/T17215 and DL\/T614. It utilizes DL\/T645-2007<\/p>\n<p class=\"p1\">protocol compatibility with MODBUS-RTU to enable data exchange with host computers, facilitating energy<\/p>\n<p class=\"p1\">measurement, power consumption monitoring, data visualization, and remote transmission. Widely adopted in<\/p>\n<p class=\"p1\">smart buildings and enterprise-level energy management systems, it supports operational assessment and control.<\/p>","protected":false},"featured_media":2894,"comment_status":"open","ping_status":"closed","template":"","meta":[],"product_brand":[],"product_cat":[34],"product_tag":[],"class_list":{"0":"post-2893","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-smart-electricity-meter","8":"first","9":"instock","10":"shipping-taxable","11":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/jrhmeter.com\/ru\/wp-json\/wp\/v2\/product\/2893","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/jrhmeter.com\/ru\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/jrhmeter.com\/ru\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/jrhmeter.com\/ru\/wp-json\/wp\/v2\/comments?post=2893"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/jrhmeter.com\/ru\/wp-json\/wp\/v2\/media\/2894"}],"wp:attachment":[{"href":"https:\/\/jrhmeter.com\/ru\/wp-json\/wp\/v2\/media?parent=2893"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/jrhmeter.com\/ru\/wp-json\/wp\/v2\/product_brand?post=2893"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/jrhmeter.com\/ru\/wp-json\/wp\/v2\/product_cat?post=2893"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/jrhmeter.com\/ru\/wp-json\/wp\/v2\/product_tag?post=2893"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}